Repair, strengthening & anchoring › Protective coatings SUDAK PROTECT EP
Solvent-free two-component epoxy protective coating suitable for contact with drinking water
- EN 1542
- EN ISO 5470-1
- EN 13501-1
Also in : Structural waterproofing & protection › Structural protection
SUDAK Maroc — ISO 9001:2015 certified company (SGS) · see the scope
SUDAK PROTECT EP is an epoxy protective coating specially developed to protect concrete and steel. Supplied as a pre-weighed two-component kit (pigmented base and hardener), it simply needs to be mixed on site to obtain a decorative finish that is easy to apply and resistant to chemical agents.
SUDAK PROTECT EP can be used safely in contact with foodstuffs and for lining drinking water tanks. Being solvent-free, it can be applied safely in confined spaces or tanks without special ventilation. The cured film does not promote bacterial growth.
Applications
- Internal protection of concrete or steel tanks containing drinking water, certain chemicals, oils or fuels.
- Impermeable, durable and chemically resistant floor and wall coating in the food processing industry, breweries, canneries and bottling plants.
- Gas and vapour barrier.
- Protective and decorative coating in laboratories, abattoirs, hospitals, garages and hangars.
- Refineries, paper mills, power stations, sugar refineries and most liquid containment areas.
Benefits
- Durable.
- Non-toxic; suitable for contact with drinking water.
- Impermeable and protective.
- High chemical resistance.
- Resistant to water at elevated temperature.
- Solvent-free.
- Easy application by brush or roller.
Technical specifications
| Property | EN standard | Value |
|---|---|---|
| Composition | — | Solvent-free pigmented two-component epoxy |
| Pot life at 25 °C | — | 30 minutes |
| Density of the mix at 25 °C | — | 1.5 kg/L |
| Initial cure at 25 °C | — | 24 hours |
| Full cure at 25 °C | — | 7 days |
| Dry film thickness per coat | — | 180 to 240 µm |
| Consumption per coat | — | 0.29 to 0.40 kg/m² |
| Bond strength to concrete | EN 1542 | Greater than the cohesion of the concrete (> 2 MPa) |
| Abrasion resistance | EN ISO 5470-1 | < 100 mg (1 kg, 1000 cycles) |
| Reaction to fire | EN 13501-1 | Class Bfl-s1 |
| Suitability for contact with drinking water | Regulation (EU) No 10/2011 | Suitable |
Typical values obtained in the laboratory at 25 °C; the “EN standard” column indicates the reference European test method. On-site performance may vary depending on application conditions.
Standards / Classification
Test methods: EN 1542, EN ISO 5470-1, EN 13501-1 (class Bfl-s1).
Suitability for contact with drinking water: Regulation (EU) No 10/2011.
Packaging
SUDAK PROTECT EP is supplied in 20 kg kits (pre-weighed components A + B).
Storage
Store under cover, in a dry place, away from direct sunlight and extreme temperatures, between +10 and +30 °C; in hot climates, store in an air-conditioned room. Before application, keep the containers for a few days between +20 and +30 °C. Shelf life: 12 months in unopened original packaging. Failure to observe storage conditions may lead to premature deterioration of the product or packaging.
Application
Substrate preparation
The substrate must be sound, smooth or semi-smooth, in concrete or metal. Careful surface preparation is essential before applying SUDAK PROTECT EP.
Concrete: the concrete must be at least 28 days old, sound, and free from excessive laitance, grease, oil and curing compound. First remove any oil or grease contamination, then the laitance by light grit blasting so as to open up blowholes. Break out damaged areas and rebuild them with SUDAK REP R4; fill blowholes and surface defects with SUDAK SURFAÇAGE before application.
Steel: remove all previous surface treatments down to bare metal. Preferably prepare by abrasive blasting (shot, corundum). Failing that, prepare by needle gun, scabbling, rotary wire brush or thermal descaling. Degrease with solvent or strong detergent. Apply before any re-oxidation of the surface.
Mixing
The kit is supplied as two pre-weighed components, base and hardener; do not add or remove any component. Pour all of the hardener into the base and mix with a low-speed drill fitted with a suitable paddle, until a uniform colour without streaks is obtained.
Application
- Apply with a good-quality roller, a short-bristle brush or an airless spray gun.
- It is recommended to apply two coats in contrasting colours to ensure complete coverage.
- Before each coat, check for pinholes; fill them if necessary with SUDAK EPOXY DUR.
- If the overcoating interval exceeds 16 hours at 40 °C or 36 hours at 20 °C, thoroughly abrade the previous coat to create a mechanical key, then remove dust with solvent. The higher the temperature, the shorter this maximum interval.
- Airless: pump ratio of 45:1 or higher, hoses of minimum 9 mm diameter, tip of 0.019 to 0.023 inch.
- Drinking water tanks: allow the full 7-day cure, then rinse thoroughly before filling.
Refurbishment and touch-up
Damaged areas to be recoated must be heavily abraded with a rotary wire brush or coarse abrasive paper to create a key. Completely remove any non-adhering coating, then proceed as for new work.
Cleaning
Clean tools and equipment with SUDAK SOLVER CL cleaner before the product has hardened. Hardened product can only be removed mechanically.
Dosage / Consumption
Consumption per coat: 0.29 to 0.40 kg/m² (dry film thickness 180 to 240 µm per coat).
Health and safety
As with all chemical products, avoid contact with the eyes, mouth, skin and foodstuffs (which may be contaminated by vapours until full cure). Wear gloves, goggles and protective clothing. In case of splashes on the skin or in the eyes, rinse immediately and thoroughly with water. In case of accidental ingestion, seek medical advice. Reseal containers after use. Refer to the Safety Data Sheet (SDS).