Joints & sealants › Polysulphide sealants (PS) SUDAK MASTIC PS
Two-component elastomeric polysulphide sealant, fuel-resistant – pourable (PG) and gun-grade (GG) versions
- EN 14188-2
- EN ISO 11600
- EN 14187-2
- EN 14187-3
SUDAK Maroc — ISO 9001:2015 certified company (SGS) · see the scope
SUDAK MASTIC PS is a two-component, cold-applied, chemically curing elastomeric sealant based on polysulphide. It offers high abrasion resistance and excellent adhesion; it resists sewage, solvents, fuels (including jet fuels), hydraulic fluids and oils, as well as dynamic movement and heavy traffic.
SUDAK MASTIC PS is available in two versions:
• SUDAK MASTIC PS-PG (pourable): self-levelling, for horizontal joints.
• SUDAK MASTIC PS-GG (gun-grade): thixotropic, non-sag, for vertical, overhead and horizontal joints.
Applications
- Joints subject to stringent chemical and fuel resistance requirements: airport runways, aprons and taxiways, service stations, petrochemical and industrial installations.
- Motorways, roads, bridge connections, ramps, stadiums, industrial floors, slabs and concrete pavements.
- Expansion joints in reinforced concrete structures: bridges, reservoirs, water treatment plants, quay walls.
- Façade joints, basements, galleries and retaining walls (gun-grade version).
- Interior and exterior applications; can be used under water once fully cured.
Benefits
- Two-component, polysulphide-based, cold-applied and chemically curing.
- High abrasion resistance and excellent adhesion.
- Withstands dynamic movement and traffic.
- Resistant to fuels, oils, hydraulic fluids, solvents and sewage.
- High resistance to ageing, UV and weathering.
- Two consistencies to cover all joint types.
Technical specifications
| Property | EN standard | Value |
|---|---|---|
| Base | — | Two-component polysulphide |
| Solids content | — | 100 % |
| Colour | — | PG: brown-black – GG: grey |
| Consistency | EN 14187-3 / EN ISO 7390 | PG: self-levelling – GG: thixotropic, non-sag |
| Movement capability (expansion / contraction) | EN ISO 11600 | 50 % / 50 % |
| Elongation at break | EN ISO 8339 | > 500 % |
| Density | EN ISO 2811-1 | 1.55 ± 0.05 g/cm³ |
| Shore A hardness | EN ISO 868 | 15 ± 5 |
| Elastic recovery | EN ISO 7389 | > 85 % |
| Pot life at 20 °C | — | 1 hour |
| Dust-free time at 20 °C | EN 14187-2 | 8 hours |
| Open to light traffic at 20 °C | — | 24 hours |
| Open to heavy traffic at 20 °C | — | 2 days |
| Full chemical resistance at 20 °C | — | 2 days |
Typical values obtained in the laboratory at 20 °C; the “EN standard” column indicates the reference European test method. Reference standards: EN 14188-2 (cold-applied joint sealants), EN ISO 11600.
Standards / Classification
Reference standards: EN 14188-2 (cold-applied joint sealants), EN ISO 11600.
Test methods: EN 14187-2, EN 14187-3, EN ISO 8339, EN ISO 7389, EN ISO 2811-1, EN ISO 868.
Packaging
- SUDAK MASTIC PS-PG (pourable): pre-weighed 12.5 kg kits (A + B).
- SUDAK MASTIC PS-GG (gun-grade): please contact us.
Storage
Store in a dry, covered area, between +10 and +25 °C. Shelf life: 12 months in the original unopened packaging.
Application
Substrate preparation
- The joint faces must be clean, dry and sound. Completely remove oil, grease, bitumen and remains of old sealants; remove any loose parts and repair spalled arrises with a SUDAK repair mortar.
- Insert the SUDAK FOND JOINT backing rod, with a diameter 10 to 25 % greater than the joint width, without damaging it. For wide joints, a semi-rigid backing material may be used, covered with a polyethylene bond-breaker tape.
- A primer is not essential on concrete, but SUDAK PRIMER MS is recommended in all cases to limit the effect of contamination, moisture and loose particles. Apply it before inserting the backing rod.
Mixing
- Components A and B are supplied in pre-weighed proportions: do not split the kit.
- Open component A and homogenise it for 1 to 2 minutes, then pour in all of component B.
- Mix for about 3 minutes with a low-speed drill (100 to 500 rpm) fitted with a suitable paddle, moving the paddle through the whole mass and scraping the sides, without entraining air. Hand mixing is not recommended.
- Use the mix within its pot life; never thin a product that has thickened.
Application
- Protect the joint edges with masking tape where appearance is important; remove it immediately after application.
- Pourable version (PG): fill the piston gun or pour directly into the joint, sliding the nozzle along the backing rod, without leaving voids.
- Gun-grade version (GG): extrude with a conical-nozzle gun applying steady pressure; fill deep joints in several passes to avoid trapping air.
- Press in and tool the sealant with a spatula.
- Pavement cracks: widen by saw-cutting a groove at least 10 mm deep and 6 mm wide before sealing.
Cleaning
Clean tools and spillages before curing, first with a cloth or tow, then with SUDAK SOLVER CL. Cured product can only be removed mechanically.
Health and safety
As with any chemical product, avoid contact with eyes, mouth, skin and foodstuffs (which may be contaminated by vapours until full cure). Wear gloves, goggles and protective clothing. In case of splashes on the skin or in the eyes, rinse immediately with plenty of water. If accidentally swallowed, seek medical advice. Reseal containers after use. Refer to the Safety Data Sheet (SDS).