Structural waterproofing & protection › Joints & waterstops SUDAK WATERSTOP
Range of PVC waterstops – internal (INT) and external (EXT) profiles, for construction and expansion joints
- EN ISO 1183-1
- EN ISO 868
- EN ISO 527-2
Also in : Joints & sealants › Expansion joints (profiles) · Underground & special civil-engineering works › Waterproofing of buried structures
SUDAK Maroc — ISO 9001:2015 certified company (SGS) · see the scope
SUDAK WATERSTOP is a range of high-quality extruded plasticised PVC waterstops, manufactured from virgin raw materials, yellow in colour. Cast into in-situ concrete, they prevent the passage of water through construction, contraction and expansion joints, both in water-retaining structures and in water-excluding structures.
The range combines the valve principle (the end bulbs, anchored in the concrete, put the profile under tension when the joint opens and ensure watertightness) and the tortuous path principle (ribs and fins that lengthen the water path). The profiles are supplied in rolls and joined on site by welding; prefabricated special pieces ensure continuity of the network at intersections.
Applications
- Water-retaining structures: reservoirs, water towers, wastewater and water treatment plant tanks, dams, locks, canals, box culverts, spillways, swimming pools, containment tanks.
- Water-excluding structures: basements, underground car parks, foundations, raft slabs, tunnels and underpasses, abutments and retaining walls, roof terraces and podium slabs.
Benefits
- Complete range of internal and external profiles, for construction and expansion joints.
- Continuous four-bulb network: valve and tortuous path principles.
- Reinforced flanges with eyelets (INT profiles) for secure fixing to reinforcement; anti-laitance fins on construction joint profiles.
- Simple on-site jointing by heat welding; prefabricated special pieces.
- Stays in place during concreting; fast, economical installation.
- Does not stain the concrete, does not cause galvanic coupling with the reinforcement, unaffected by common concrete admixtures.
- High elasticity and good abrasion resistance; yellow colour easily identifiable on site.
Technical specifications
Technical data – material
| Property | EN standard | Value |
|---|---|---|
| Material | — | Plasticised PVC, virgin raw materials |
| Colour | — | Yellow |
| Density | EN ISO 1183-1 | 1.3 to 1.4 |
| Shore A hardness | EN ISO 868 | ≥ 75 |
| Tensile strength | EN ISO 527-2 | ≥ 15 MPa |
| Elongation at break | EN ISO 527-2 | ≥ 300 % |
| Water absorption | EN ISO 62 | ≤ 0.15 % |
| Alkali resistance – change in mass / hardness | — | +0.063 % / −3.2 points |
| After accelerated extraction – tensile strength / elongation | — | ≥ 15 MPa / ≥ 300 % |
| Service temperature | — | −35 to +55 °C |
| Welding temperature | — | 160 to 180 °C |
Minimum guaranteed values; the “EN standard” column indicates the reference European test method.
Service data
| Property | Value |
|---|---|
| Permissible water pressure, without joint movement | Up to 10 m (150 mm profiles) – up to 100 m (200 and 250 mm profiles) |
| Permissible water pressure, at maximum movement | Up to 40 m (200 and 250 mm profiles) |
| Permissible joint movement | Up to 10 mm (resultant of x, y, z movements) |
| Maximum joint width | 40 to 50 mm depending on the profile |
Standards / Classification
Test methods: EN ISO 1183-1, EN ISO 868, EN ISO 527-2, EN ISO 62.
Packaging
Profiles supplied in 20 m rolls. Special pieces supplied individually.
Storage
Store under cover, away from direct sunlight and extreme temperatures.
Application
- INT profiles: hold the profile firmly in position during concreting, centred on the joint and at mid-depth, by tying it to the reinforcement through the eyelets in the reinforced flanges (the eyelets, located outside the bulbs, do not create a water path). Leave sufficient space between the reinforcement and the waterstop to allow proper compaction of the concrete.
- EXT profiles: on blinding concrete, simply lay the profile centred on the joint axis, generally without fixing. On vertical formwork, nail through the nailing flange leaving the nail heads protruding; these will be cast into the concrete and prevent the profile from moving when the formwork is struck.
- Vibrate the concrete carefully around the waterstop so as to leave no voids or porous areas; a self-compacting concrete designed with the SUDAK SuperPlast range makes filling easier.
- For expansion joints, fill the joint with a SUDAK FOND JOINT backer rod or a SUDAK Filler Board, then seal with a SUDAK sealant.
Health and safety
Non-hazardous product under normal conditions of use. When welding, work in a ventilated area and avoid inhaling fumes; wear gloves when handling the heated blade.