Repair, strengthening & anchoring › Protective coatings SUDAK PROTECT NOVOLAC
Solvent-free, high-build novolac epoxy coating with very high chemical resistance – EN 1504-2
- EN 1504-2
Also in : Structural waterproofing & protection › Structural protection
SUDAK Maroc — ISO 9001:2015 certified company (SGS) · see the scope
SUDAK PROTECT NOVOLAC is a two-component coating based on novolac epoxy resin, 100 % solids, solvent-free and highly cross-linked. It forms a dense, glossy, hard and impermeable film with exceptional chemical resistance to acids, alkalis and hydrocarbons, over a pH range of 1 to 14 at 25 °C. It protects concrete and steel in aggressive chemical environments.
SUDAK PROTECT NOVOLAC is applied in two coats for a minimum total dry film thickness of 400 µm; greater thicknesses may be specified. It can be reinforced with glass fibre cloth (laminated system) or broadcast with SUDAK ANTIGLISSE for a heavy-duty slip-resistant floor coating. Complies with standard EN 1504-2, principles 1.3, 2.2, 5.1, 6.1 and 8.2.
Applications
- Internal protection of concrete or steel tanks and vessels containing aggressive chemicals, oils, acids, solvents and alkalis.
- Wastewater and sewage treatment plants, desalination plants.
- Chemical and petrochemical industry, refineries, fertiliser and crop protection product plants.
- Food processing industry, power stations, paper mills.
- Containment bunds, drum storage areas, loading bays and ramps (with SUDAK ANTIGLISSE).
- Glass-fibre-cloth-reinforced laminated coating for highly exposed structures.
Benefits
- 100 % solids, solvent-free, VOC-free.
- Excellent chemical resistance to acids, alkalis and hydrocarbons, from pH 1 to 14.
- Excellent adhesion to properly prepared concrete, to steel and to many substrates; compatible with damp concrete.
- Excellent abrasion and impact resistance.
- Glossy, very dense and hygienic finish; non-toxic cured film.
- System can be reinforced with glass fibre cloth or made slip-resistant depending on exposure.
Technical specifications
EN 1504-2 performance – guaranteed thresholds
| Property | EN standard | Value |
|---|---|---|
| Adhesion by direct pull-off (rigid system, with traffic) | EN 1542 | ≥ 2.0 MPa |
| Adhesion to damp concrete | EN 13578 | ≥ 1.5 MPa |
| Abrasion resistance | EN ISO 5470-1 | < 3000 mg |
| CO₂ permeability | EN 1062-6 | SD > 50 m |
| Water vapour permeability | EN ISO 7783 | Class I (SD < 5 m) |
| Capillary absorption and water permeability | EN 1062-3 | w < 0.1 kg·m⁻²·h⁻⁰·⁵ |
| Resistance to severe chemical attack | EN 13529 | Average reduction in hardness < 50 % |
| Impact resistance | EN ISO 6272-1 | Class III (≥ 20 N·m) |
| Shore D hardness | EN ISO 868 | > 70 |
| Reaction to fire | EN 13501-1 | Euroclass B-s1, d0 |
| Dangerous substances | EN 1504-2 | Complies with § 5.3 |
Minimum values guaranteed in accordance with the requirements of standard EN 1504-2; the “EN standard” column indicates the reference European test method.
Product characteristics
| Property | EN standard | Value |
|---|---|---|
| Composition | — | Two-component novolac epoxy |
| Solids content | — | 100 % – VOC: nil |
| Appearance | — | Glossy |
| Density of the mix | EN ISO 2811-1 | 1.35 |
| Tensile strength | EN ISO 527-2 | 20 MPa |
| Flexural strength | EN ISO 178 | 20 MPa |
| Compressive strength | EN ISO 604 | 70 MPa |
| Pot life at 23 °C | — | 45 min |
| Tack-free time at 23 °C | — | 4 hours |
| Overcoating time at 23 °C | — | 4 to 16 hours |
| Full cure at 23 °C | — | 7 days |
| Service temperature | — | −20 to +60 °C |
| Dry film thickness per coat | — | 200 µm maximum on vertical surfaces |
Typical values obtained in the laboratory at 25 °C; the “EN standard” column indicates the reference European test method. On-site performance may vary depending on application conditions.
Standards / Classification
Complies with standard EN 1504-2, principles 1.3, 2.2, 5.1, 6.1 and 8.2.
Packaging
SUDAK PROTECT NOVOLAC is supplied in pre-weighed 4-litre kits (base + hardener).
Storage
Store under cover, in a dry, air-conditioned room, between +5 and +30 °C, away from direct sunlight, in unopened original packaging. Shelf life: 12 months.
Application
Substrate preparation
- Concrete: at least 28 days old or with moisture content below 5 %, dry, sound, free from laitance, oil, grease, wax and any contamination. Prepare mechanically by shot blasting or grit blasting to open up blowholes and obtain a CSP 3 roughness profile. Fill blowholes and defects with SUDAK EPOXY DUR or SUDAK MORTAR EP.
- Steel: abrasive blast to grade Sa 2½ (ISO 8501-1), roughness of 50 to 75 µm. Coat freshly blasted steel as soon as possible, before any re-oxidation.
- Primer: SUDAK PROTECT NOVOLAC is applied without a primer; on porous concrete, first apply SUDAK PRIM SOL EP.
Mixing
- Store the product for 48 hours between 15 and 25 °C before use.
- Pour all of the hardener into the base; never split kits or add anything.
- Mix with a slow-speed electric mixer until uniform in colour and consistency, carefully scraping the sides and bottom of the container.
Application
- Apply immediately after mixing, with a stiff nylon brush, a short-pile roller or a squeegee followed by a roller pass, in a continuous coat of uniform thickness (200 µm maximum per coat on vertical surfaces).
- Apply the second coat within the overcoating window (4 to 16 hours at 23 °C).
- Glass fibre cloth reinforcement: embed the cloth into the fresh first coat with a debubbling roller, then apply the second coat within the overcoating window.
- Slip-resistant finish: apply a first coat of at least 200 µm and broadcast SUDAK ANTIGLISSE to refusal; after initial cure, vacuum off the excess then apply the finishing coat, taking care to seal the surface completely. Carry out a trial panel.
- Allow to cure for at least 7 days before any prolonged chemical exposure.
Precautions for use
- Substrate, air and product temperatures above +5 °C; at 5 °C, viscosity increases and makes application difficult.
- Do not apply to substrates subject to rising damp or a risk of osmosis, nor if the relative humidity of the substrate exceeds 75 %; do not apply if air humidity exceeds 90 %.
- Do not use for water immersion above 60 °C; above 90 °C in dry heat, loss of gloss and change of colour may occur.
- Like all epoxies, the coating may yellow, lose its gloss and chalk in sunlight or on contact with certain products; this does not affect its protective performance.
Cleaning
Clean tools and equipment with SUDAK SOLVER CL cleaner before the product has hardened. Hardened product can only be removed mechanically.
Dosage / Consumption
A 4 L kit covers 10 m² at 400 µm total dry film thickness (two coats). Theoretical consumption; actual consumption varies according to the substrate and wastage.
Health and safety
Wear protective clothing, gloves and goggles. In tanks or confined spaces, provide forced ventilation during application and until cured, and equip applicators with suitable respiratory protection. Do not leave large quantities of mixed product (over 300 g) in the container: the exothermic reaction may cause heating and fumes; if this occurs, cover with sand and move to a ventilated area. In case of splashes on the skin or in the eyes, rinse immediately; in case of ingestion, seek medical advice. Refer to the Safety Data Sheet (SDS).