Admixtures & additives for mortar and concrete › Fibres SUDAK FIBRES
Monofilament polypropylene fibres for cement-based systems
- EN 14889
Also in : Industrial & resin floor coatings › Fibres for slabs
SUDAK Maroc — ISO 9001:2015 certified company (SGS) · see the scope
SUDAK FIBRE is a high-performance monofilament polypropylene micro-synthetic fibre developed as an anti-cracking additive for concrete and mortar.
Applications
- SUDAK FIBRE is used to inhibit the formation of small cracks that can occur due to plastic shrinkage, premature drying or early thermal changes. Specifically designed for crack control in cement-based materials, covering areas such as ready-mixed concrete, precast concrete, conventional sprayed concrete, render mortars, screeds, thin-section walls, water-retaining structures, industrial floors, marine or corrosive environments…
Benefits
- Can replace anti-crack mesh in factory and warehouse floors.
- Inhibits intrinsic cracking of concrete.
- Disperses uniformly throughout the mix.
- Improves finishing characteristics.
- Improves the durability of concrete.
- Increases impact and abrasion resistance.
- Rustproof.
- Impervious to attack by alkalis and acids
- Improves fire resistance
Technical specifications
| Constituents | Polymerised polypropylene |
|---|---|
| Specific gravity | 0.91 g/cm³ |
| Number of fibres | +120 million/kg |
| Alkali content | Nil |
| Sulphate content | Nil |
| Chloride content | Nil |
| Air entrainment | The air content of the concrete will not be significantly increased |
| Fibre diameter | 18 microns |
| Fibre length | 12 mm |
| Surface area | 140 m²/kg min. |
| Young's modulus | 6 GPa |
| Tensile strength | 500 MPa |
| Melting point | 165 °C |
| Magnetism | Non-magnetic |
| Standards | EN 14889 ASTM C1116, ASTM D7508, ICC AC 32 |
Standards / Classification
EN 14889; ASTM C1116; ASTM D7508; ICC AC 32.
Packaging
In 900 g doses in soluble, degradable paper bags.
Application
SUDAK FIBRE can be added to the concrete together with the aggregates, or directly into the batching plant mixer or the concrete mixer. For better homogenisation, the mixing time of the fibres with all the constituents, once they have all been introduced, must be at least 45 s. SUDAK FIBRE can also be added to the truck mixer once the concrete is inside. The minimum mixing time at the drum's maximum rotation speed is then 1 minute per cubic metre.
Dosage / Consumption
One dose of 900 g per cubic metre of concrete. However, trials are recommended to determine the optimum dosage. Other dosages are possible depending on the project specification.
Health and safety